Room Monitor System Series

RM-R100-TLQ

Sensor

The Room Monitor indicates when a room, like a bathroom or fitting room, is occupied or vacant. The highly visible indicator can be seen from a distance, saving time previously spent checking if a room was occupied. The Room Monitor can increase productivity and customer traffic flow by reducing idle time.

 

  • CE

FEATURES

RM-R100-TLQ

  • • Programmable to use PIR (movement), phototransistor (light), or door sensor input (switch) to detect occupancy
    • 1-Room indicator has a programmable, built-in buzzer for service input
    • Programmable reminder, 3~30 min
    • Simple to install – micro USB or terminal block (5~12VDC)
    • Suitable to use in restrooms, fitting rooms, etc. to monitor occupancy
    • Indicators can be paired with up to 15 Sensors per channel
    • Each sensor can transmit to unlimited number of indicators
    • Service button connections available*
    *RM-R100-TLQ and RM-R100-RB1Q only.

SPECIFICATIONS

Color Camera
Type Room Occupancy Monitor
Description Sensor
Indicators LED
Current draw Standby: 2mA@12VDC; Active: 15mA@12VDC max.
Transistor ground rating 100mA max.
PIR Sensor range ~16' (5m)
Phototransistor sensitivity ≥320Lux
Door input NO or NC
RF Range* 100' (30m) *Actual operating range will vary greatly depending on the installation and operating environment.
Operating frequency 433.92MHz
Operating voltage 5VDC via micro USB or 5~12 VDC via terminal block
Connections Screw terminals
Operating temperature -4°~167° F (-20°~75° C)
Dimensions 2-1/2x15/16x1-7/8 in (64x24x48 mm)
Weight 1.8-oz (50g)